7.3. Power supply
The MTC 6 is equipped with a galvanically separated, integrated DC power supply.
Power is connected to the underside of the unit using a Phoenix Contact plug. There is
no power switch.
NOTICE:
Property
damage
The MTC 6 must only be connected to a SELV circuit.
*)
Ensure that there is a suitable disconnecting device such as a
power switch or circuit breaker in the power supply circuit. Ensure
that the disconnecting device isolates all supply voltage lines.
The DC+ connecting cable must be protected by a fuse
(30 AT max.).
The ignition connecting cable must be protected by a fuse of the
following type: 5x20 mm T 125 mA L / 250 V, for example, a
Wickmann 195-125 mA / 250 V.
*) The SELV circuit is a secondary circuit that is designed and protected so that its voltages will
not exceed a safe value both when operating correctly or if a single error occurs.
Make sure that the connecting cables are laid without kinks and
are protected.
Use only original power supply cables from Advantech-DLoG
Advantech-DLoG power cables meet the specific requirements for
low-temperature flexibility, UV resistance, oil resistance, etc.
• Use only original power supply cables from Advantech-DLoG.
If other power supply cables are used:
• The user/operator of the industrial PC is solely responsible for the