User`s manual

Device description – Technical specifications
MTC 6 Series User’s Manual V2.00 25
Power
consumption
Power consumption MTC 6/10: typically 20 W
Power consumption MTC 6/12: typically 25 W
Power consumption MTC 6/15: typically 25 W
Standby typically 1 W (valid for all MTC 6 devices)
*)
The SELV circuit is a secondary circuit that is designed and protected so that its
voltages will not exceed a safe value both when operating correctly or if a single error
occurs.
Power supply fuses
The symbol for the fuse is FA. You will find the exact position on the sticker located on
the connection plate.
Power supply Fuse type Examples
DC-11
DC-13
5 x 20 mm T 10 A
H / 250 V
Bussman S505-10A
Wickmann 181-10A
Littelfuse 215 10
Siba 70 007 65 10A
Elu 179200 10A
or similar devices produced by other
manufacturers
DC-12
DC-14
5 x 20 mm T 4 A
H / 250 V
Bussman S505-4A
Wickmann 181-4A
Littelfuse 215 04
Siba 70 007 65 4A
Elu 179200 4A
or similar devices produced by other
manufacturers