Instruction manual

Automatic Switch-off
DLoG Config Manual V3.10 23
Settings
The settings on the DLoG MTC 6 correspond to the MPC/IPC/ITC settings in
section 8.1 Configuration dialog on DLoG MPC, IPC, ITC.
Switch on
with ignition The Industrial PC switches on automatically when the ignition
is started. It cannot be switched on with the power key.
with ignition
and power key
The Industrial PC can be switched on with the power key if
the ignition is on. It cannot be switched on with the power
key alone.
with power key The Industrial PC can be switched on
with the power key.
always on The DLoG Industrial PC switches on as soon as it is supplied
with power. It is not necessary to press the power key or start
the ignition.
Switch off
with ignition Automatic switch-off is activated when the ignition is switched
off. The power key shortens the defined after-run time and
initiates computer shutdown.
with ignition
and power key
Automatic switch-off is activated when the ignition is switched
off. The power key must be pressed to shut down the
Industrial PC.
with power key The Industrial PC is shut down or switched off with the power
key.
only by system
shutdown
The computer cannot be switched off using the ignition or the
power key; it has to be shut down in the Start menu.