User`s manual
APPENDIX B AWS-8259 Power Supply
Specifications 63
Line regulation:
The output line regulation for each output is less than ±1%, when mea-
sured at each output’s respective rated load and under ±10% changing
input voltage conditions.
Load regulation:
The values for each of the following output numbers were obtained by
changing each output load ±40% from the 60% rated load, whilst simul-
taneously keeping all other outputs at 60% of their respective rated loads.
Table B-9: 24Vdc Power Supply load regulation
Power good signal:
When the power is turned on, the power good signal will acti-vate 100 to
500 ms after all output DC voltages are operating within their respective
regulation limits.
Power fail signal:
This will activate at least 0.5 ms before any of the output voltages fall
below their respective regulation limits.
Output No. Load regulation
1 ±4%
2 ±5%
3 ±3%
4 ±3%