AWS-8248V Industrial Workstation with 15" LCD Display User’s Manual
Copyright This document is copyrighted September, 2002, by Advantech Co., Ltd. All rights are reserved. Advantech Co., Ltd. reserves the right to make improvements to the products described in this manual at any time. Specifications are thus subject to change without notice. No part of this manual may be reproduced, copied, translated, or transmitted in any form or by any means without the prior written permission of Advantech Co., Ltd.
FCC Class A This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy. If not installed and used in accordance with this user's manual, it may cause harmful interference to radio communications.
Packing List Before you set up the AWS-8248V, make sure that the following items have been included in your package, and that this manual is in good condition. If anything is missing or damaged, contact your dealer immediately: • • One AWS-8248V industrial workstation with 15" flat panel display One accessory box, including: - One power cord - One keyboard transfer cable - One CD-R for IC & HMI products Driver/manual - Flat gray cable for 3.
Safety Instructions 1. Read these safety instructions carefully. 2. Keep this User's Manual for later reference. 3. Disconnect this equipment from any AC outlet before cleaning. Use a damp cloth. Do not use liquid or spray detergents for cleaning. 4. For plug-in equipment, the power outlet socket must be located near the equipment and must be easily accessible. 5. Keep this equipment away from humidity. 6. Put this equipment on a reliable surface during installation.
Wichtige Sicherheishinweise 1. Bitte lesen sie Sich diese Hinweise sorgfältig durch. 2. Heben Sie diese Anleitung für den späteren Gebrauch auf. 3. Vor jedem Reinigen ist das Gerät vom Stromnetz zu trennen. Verwenden Sie Keine Flüssig-oder Aerosolreiniger. Am besten dient ein angefeuchtetes Tuch zur Reinigung. 4. Die NetzanschluBsteckdose soll nahe dem Gerät angebracht und leicht zugänglich sein. 5. Das Gerät ist vor Feuchtigkeit zu schützen. 6.
Contents Chapter 1 Introduction ......................................................2 1.1 Introduction ....................................................................... 2 1.1.1 1.2 1.3 1.4 Chapter Features:.......................................................................... 3 Specifications .................................................................... 3 Front and rear panel layout................................................ 5 Dimensions.........................................
AWS-8248V User’s Manual viii
CHAPTER Introduction • Introduction • Specifications • Front and rear panel layout • Dimensions 1
Chapter 1 Introduction 1.1 Introduction The AWS-8248V is a 14-slot, 15” TFT LCD workstation. It is a great update to the AWS-8248 product line by offering more expansion capability, a larger LCD screen, and increased usability, all at an even more competitive price. The AWS-8248V also provides an additional major feature for users: Easy maintenance. Using three card-cages and thumbscrew fasteners, the AWS-8248V makes maintenance quick and easy.
1.1.1 Features: • Low cost 15", 14-slot TFT LCD workstation, and 1024 x 768 resolution • Three card-cage design: Easy to maintain add-on cards, CPU card and power supply. • Two 3.5î HDDs with mobile rack drive & CD-ROM drive in back of chassis • Equipped with the On-Screen Display (OSD) operation keypad on the front panel • IP65/NEMA 4, Aluminum panel. 1.
- Backlight lifetime: 50,000 hours - Interface: Direct VGA - LCD defect specification: refer to Advantech web site Front Panel • Keypads: One with 39 operating keys, one with 10 function keys and 10 programmable macro function keys • Keyboard connector: Pre-wired 5-pin DIN connector with dustprotection cover on front and rear panel • Switches: Reset and power on/off.
24 VDC input 250 W (optional) • Input voltage: 19 ~ 32 VDC • Output voltage: +5 V @ 25 A; +12 V @ 10 A; -5 V @ 1.0 A; -12 V @ 1.0 A • MTBF: 100,000 hours Environmental specifications • Operating temperature: 0 ~ 50° C (32 ~ 122° F) • Relative humidity: 5 ~ 85% @ 40° C, non-condensing • Vibration: 5 ~ 17 Hz, 0.1" double-amplitude displacement 17 ~ 500 Hz, 1.0 G peak to peak. 1.3 Front and rear panel layout Figure 1.
Figure 1.2: Rear panel layout 1.4 Dimensions Figure 1.
CHAPTER 2 System Setup • General • Rack Mounting • Panel mounting
Chapter 2 System Setup 2.1 General When you receive your workstation you will find a backplane, power supply, and floppy disk drive already installed. Further setup of the AWS-8248V is easy. All you have to do is slide out its work drawer module, install a CPU card, optional hard disk drive and whatever additional I/O cards your application requires. Warning! 1. Do not begin your installation until you are sure there is no power flowing within the AWS8248V.
2.2 Rack mounting The AWS-8248 can be mounted in a 19" rack. Ensure that all addi-tional equipment has been installed correctly and that the cabling has been reattached. (See Fig. 2-7) Remove the screw covers on the front panel. Attach the case to the rack using screws on both sides. Figure 2.
2.3 Panel mounting Panel mounting the AWS-8248 is easy. Just line up the holes in the panel aperture and the holes on the panel, and then secure the AWS-8248 to the panel with the mounting bolts. Figure 2.
CHAPTER 3 Programming KBT-2002 Macro Keys • Introduction • Macro Keys • Using Main.
Chapter 3 Programming KBT-2002 Macro Keys 3.1 Introduction The KBT-2002 is equipped with programmable function keys (macro keys) that greatly enhances the operating interface. Macros, which are far more powerful than batch files; automate the most commonly used input sequences. They extend their functional reach within application programs. 3.2 Macro keys Macro keys (SF1 , SF2 ,...SF10) Ten programmable macro keys are located on the front panel of the workstation. Macro keys (SF11 , SF12 ,...
There ís an example within the subdirectory of the utility disk. Go into this subdirectory and look for a .txt file that corresponds to your workstation, for example, AWS8420.txt. You can use this file under the macro key edit program to practice. Note 1: The keyboard translator utility main.exe program can be run under DOS mode only. Note 2: The following windows illustrations are examples only. You must follow the instruction and pay attention to the instructions which appears on you screen. 3.
Choose Load in the function and press the enter key. Key in the file name that you edited in this program before. To practice, you can choose, for example, the AWS8420.txt in the example in the utility disk. After reading the file, press Esc key to leave this mode. Whether you have loaded the old file or not, choose Edit in the main menu and press enter to go into the edit mode. You can see the operating guide at the bottom of the screen.
n this sub screen, you can key in any character string that you want to see when pressing this macro key, or any signs. You can also key in the names of the function keys of the keyboard; but please add a [ ] sigh. The number characters you key in should be under 78. After editing, press Esc key to go back to the edit mode, then you can choose other macro keys to edit. If there is no SF 11, SF1 2,...SF30 on your workstation, please ignore and do not edit them.
Choose Run in the main menu, and press Enter to go into the Run (programming) mode. You will see a sub-screen for upper key setting OFF= Press both character and upper key in the same time ON= Press upper key. Then key the character for upper layer. Press the upper key again for the lower layer PS: some membrane keypad has Upper indicator (light on=upper status) After setting the upper key, press Enter. Choose if you need the beep sound when you press the macro keys.
After the beep sound setting, press Enter and you will be asked to key in a .pad file name. Please refer to chapter 1.3. Do not use any other file names other than that of this workstation, or character definition errors might arise! After keying the file name, press Enter, The system will start to read the data in the file together with the data in the .txt file that you just edited and save to the keyboard translator board of this workstation.
After the system finished the programming, you will see a sub-screen that tells you to repeat the process again or press Esc to leave the Run mode. Note: There might be transition error when the connection cable between the CPU card and the keyboard translator is too long. If the error occurs, please turn off the workstation and use a shorter cable, then reboot the workstation and run the main.exe program again.
Appendix A Display Timing Mode & OSD • Supported input timing modes • OSD operation keypad • OSD function and operation
Appendix A Display Timing Mode and OSD A.1 Supported Input Timing Modes The following nineteen kinds of timings have already been programmed in this module. The input synchronous signals are automatically recognized. Table A.1: Display Modes Table Chroma Resolution 2325 Timing No. HSYNC / KHz (+/-) VSYNC / Hz (+/-) PIXEL RATE / MHz #008 VGA 640 * 350 31.469 (+) 70.087 (-) 25.175 #011 VGA 640 * 400 31.469 (-) 70.087 (+) 25.175 #013 VGA 640 * 480 31.469 (-) 59.941 (-) 25.
Table A.1: Display Modes Table Chroma Resolution 2325 Timing No. HSYNC / KHz (+/-) VSYNC / Hz (+/-) PIXEL RATE / MHz REMARK #008 VGA 640 * 350 31.469 (+) 70.087 (-) 25.175 #041 VESA 1024-75 60.023 (+) 75.029 (+) 78.750 #042 VESA 1024-85 68.677(+) 84.996(+) #066 OAK 800 * 600 35.156(+) 56.160 (+) 36.000 * #035 #067 OAK 1024 * 768 48.077 (+) 59.797 (+) 36.000 * #038 #074 640 * 400 37.861 (-) 85.081 (+) 31.500 * #032 and #034 94.500 #075 720 * 400 37.927 (-) 85.038 (+) 35.
Note 2: This module recognizes the synchronous signals with near preset timing of the frequency of the HS and Vsync, even in the case that the signals other than the preset timing that were entered. Note 3: Because adjustments may not fit, such as differing magnifying ratios or, in the case that you use it except for the display timing that was preset. A.2 OSD Operation Keypad The OSD keypad, including the six keys and two color indicators, is designed as the OSD operation interface.
A.3 OSD function and operation Auto-adjustment process or to adjust manually: 1. Press [Sel] button to display the OSD Menu shown below. 2. Press 3. Press [Sel] button to select the menu option. 4. Press 5. Press [Exit] button or wait until time out to save changes and exit the menu or sub-menu. or or button to scroll to the desired menu option. button to adjust the setting. Figure A.
Table A-3 is the OSD menu hierarchy and function description. Table A.3: OSD Functionality Main Menu Sub Menu Brightness Reset Brightness Contrast Contrast Reset Contrast Adjust RGB contrast simultaneously R Sub Contrast Reset R Contrast Adjust R contrast G Sub Contrast Reset G Contrast Adjust G contrast B Sub Contrast Reset B Contrast Adjust B contrast H. Size Reset H. Size Adjust clock number per line Clock Phase Reset Clock Phase Adjust phase of ADC sample clock H.
Appendix B Power Supply Specification • 250 watt power supply • -48 VDC power supply • 24 VDC power supply
Appendix B Power Supply Specifications B.1 Supported Input Timing Modes The AWS-8248 off-line switching power supply is ideal for use in workstations. It has been designed to meet UL, CSA and TUV safety standards. It has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. B.1.
B.2 -48 V DC power supply The following specifications describe the physical and electrical characteristics of a 310 W, four output, DC to DC switching power supply housed in a standard size PS/2 casing. B.2.1 Specifications Input voltage: 36~72V (continuous operation) -48 VDC (normal operation) Input current: 10 A max. @ -48 VDC input Inrush current: 5 A max. @ -48 VDC input Efficiency: 70% min. @ full load and normal line voltage Output characteristics: Output voltage Max Load Total Max.
Overshoot (resistive load): Any output overshoot when the power is turned on does not exceed 10% of the nominal output voltage. Output power: Maximum continuous: 310 W Power good and power fail signals (optional): When the power is turned on, the power good signal will activate 100 to 500 ms after all output DC voltages are operating within their respective regulation limits. The power fail signal will activate at least 1 ms before the +5 V output voltage falls below its regulation limit.
Reset time: When the power supply has automatically shut down, and the short circuit, over-current and/or over-voltage conditions have ceased to exist, power will be automatically recycled to restart the power supply within 3 seconds of such return to normal conditions. No load start: When the power supply is switched on but with no load connected, the power supply does not get damaged, and it is still completely safe for users.
DC Output wire list All DC output cables use UL 1007 type wires.
B.3 24 VDC power supply This is a DC to DC switching mode power supply with a 24 VDC input. Input voltage:+19 ~ +32 VDC (normal operation) Input current:16 A max. @ +24 VDC input Inrush current:10 A max. @ +24 VDC input Output load range: Output voltage Max Load Total Max. Output +3.3V 25A(Max. 150W) +5V 30A(Max. 150W) +12V 12A -5V .5A -12V 1A +5V sb 1A 250W Table B.3: 24VDC power supply output load range At the factory, the +5 V output was set between 5.00 and 5.
Line regulation: The output line regulation for each output is less than ±1%, when measured at each output’s respective rated load and under ±10% changing input voltage conditions. Load regulation: The values for each of the following output numbers were obtained by changing each output load ±40% from the 60% rated load, whilst simultaneously keeping all other outputs at 60% of their respective rated loads.
Appendix C Touchscreen (optional) • Installation of touchscreen driver
Appendix C Optional Touchscreen C.1 Specifications Electrical Operating Voltage: 3.3 to 5 VDC typical Sheet Resistance: 220 ± 30% W/square Linearity: +/- 1.5% full scale linearity error in either direction. Insulation Resistance: > 20 ΜΩ @ 25 VDC.
Durability Point Activation Life: 1 Million activations on a single point with a 5/8” diameter silicone finger with a 350g load at 2 Hz Character Activation Life: >100,000 characters written within a 20mm x 20mm C.2 Installation of Touchscreen Driver The touchscreen for the AWS-8248 Series provides drivers for use with MS-DOS,Windows 3.1, 95, 98, NT, 2000, XP.
AWS-8248V User’s Manual 40