ARK-3389 User Manual 12
2.4.2 COM1 Connector
The ARK-3389 provides a D-sub 9-pin connector, which offers one stan-
dard RS-232 serial communication interface port of COM1.
2.4.3 COM2 Connector
The ARK-3389 provides a D-sub 9-pin connector, which offers one RS-
232/422/485 serial communication interface port for COM2. The default 
setting of COM1 is RS-232. Please refer to section 3.3 “Jumper Settings” 
and Chapter 6 “Full Disassemblly Procedure” to set up RS-422 or RS-
485.
The RS-422/485 mode of COM2 can be supported by replacing the inter-
nal COM 2 cable with the new cable (Part Number of 1700001967), and 
adjusting the jumper inside of system. The new cable (pn.1700001967) 
has been stored in the accessory box of the product carton.
Table 2.5: COM1 standard serial port pin assignments
Pin Signal Name
1 DCD
2RxD
3TxD
4DTR
5GND
6DSR
7RTS
8CTS
9RI