User manual

ARK-3382 User Manual 14
2.3.3 COM2 Connector
The ARK-3382 provides a D-sub 9-pin connector, which offers one RS-
232/422/485 serial communication interface port of COM2. The default
setting of COM1 is RS-232. Please refer to section 4.1 “Jumper Settings”
and section 6 “Full Disassembly Procedure” to set up RS-422 or RS-485.
The RS-422/485 mode of COM2 can be supported via replacing the
internal COM 2 cable and using the new cable (Part Number of
1700001967), and adjusting the jumper inside of the system. The new
cable (pn.1700001967) has been stored in the accessory box of the prod-
uct carton.
Figure 2.8: COM 2 connector
Note: NC represents “No Connection”.
Table 2.6: COM2 standard serial port pin assignments
RS-232 RS-422 RS-485
Pin Signal Name Signal Name Signal Name
1DCD Tx- DATA-
2RxD Tx+ DATA+
3 TxD Rx+ NC
4DTR Rx- NC
5 GND GND GND
6 DSR NC NC
7 RTS NC NC
8 CTS NC NC
9RI NC NC
15
9
6
324
78