User manual
ACP-4362/4360 User Manual 36
5.2.2 Switch Settings
The alarm board is designed to connect with up to 7 fans. User can set the fan num-
ber by adjusting the switch, SW1, on the alarm board.
Table 5.9: J1, External buzzer
Pin 1 Buzzer Pin 2 +5 V
Table 5.10: SW1, Fan number select switch
Pin 1 GND Pin 5 GND
Pin 2 FAN_SEL1 Pin 6 FAN_SEL3
Pin 3 GND Pin 7 GND
Pin 4 FAN_SEL2 Pin 8 RESET
Table 5.11: SW1, Fan number setting
Fan Number SW 1-1 SW 1-2 SW 1-3 SW 1-4
0 OFF OFF OFF OFF
1ONOFFOFFOFF
2 OFF ON OFF OFF
3 (default) ON ON OFF OFF
4OFFOFFONOFF
5ONOFFONOFF
6 OFF ON ON OFF
7 ONONONOFF
Note! Connect the fan connectors in the correct sequence: if two fans are set
on SW1, the correct method is to connect them into connectors FAN1
and FAN2. If the two fans are connected to other fan connectors, out of
sequence, such as FAN1 and FAN3 or FAN2 and FAN3 or FAN3 and
FAN4, instead of FAN1 and FAN2, then the alarm will not function cor-
rectly.