User manual
25 ACP-4362/4360 User Manual
Chapter 3 Operation
3.6.2 Replacing the Redundant Power Supply Module
1. Turn off the power switch of the failed power supply module.
2. Unplug the power cord from the failed module.
3. Loosen the screw on the failed module and then grab the handle to gently pull it
out. (see Figure 3.9)
4. Make sure that the new power supply module is the same rating as the currently
installed one.
5. Slide the power supply module inward until it locks into the right position.
6. Secure the screw and replace the handle. Then plug in the power cord.
Figure 3.9: Replacing the power supply module
Figure 3.10: Power cord plug orientation on the socket
Note! When you plug two power cords into the same bank of sockets, please
align them in the same direction (see Figure 3.10).