User manual

23 ACP-4362/4360 User Manual
Chapter 3 Operation
3.4.2 Replacing the fan behind the SATA backplane
1. Remove the top cover.
2. Pull out the clip on top of the fan unit so that the fan detaches from the fan
enclosure.
3. Unplug the fan power connector on the SATA HDD backplane. (see Figure 3.6)
4. Plug the power connector of the new fan into the SATA HDD backplane first.
5. Put a new fan into the fan enclosure carefully until it is locked by the tab. Be
sure to install it securely in the enclosure.
6. Replace the top cover and fasten it.
Figure 3.6: Replacing the fan behind the SATA HDD backplane
3.5 Cleaning the Filters
The filter functions to block dust or particles from the work environment and to extend
the longevity of the system. It is recommended to clean the filters periodically. There
are two reusable and washable filters behind the front door and the front of the fan.
To remove and clean the filter, proceed as follows.
1. Open the front door.
2. Pull out the filter behind the front door by pushing the two clips; pull out the fan
filter by pushing the hook and then slide it to the right.
3. Clean the filter with a soft brush and wash the dust away from the filter with flu-
ent water. Then dry it. (see Figure 3.7)
4. Replace the filter inside the unit.
Figure 3.7: Cleaning the filters