7.3.9 Manual Rebuild
1. Select “Manage Arrays” from the main menu
2. Select and highlight the disk you want to rebuild, and then press
“Ctrl + R” to Rebuild
7.3.10 Verifying Drives
If having a mismatch of data during a build of RAID 1, you can verify the
drives with following steps:
1. Select the drives you want to verify
2. Press “Ctrl+S”
3. When the Verify is complete, you will be notified with any errors
found during the Verify operation.
7.4 Installing the driver
7.4.1 Installing the driver in Windows system
Be sure to create the array before entering or installing the operating sys-
tem.
1. Restart the computer
2. Press <Ctrl> + <A> to enter the “Adaptec Embedded SATA Hot
RAID Controller” to setup the SATA array system
3. When the array is build, insert the driver CD and restart the system
4. Windows searches the disk for a suitable driver
5. When the Adaptec Embedded Serial ATA HostRAID driver is
found, press “Enter”. Follow the instructions to complete your
installation.