User manual
Chapter 6 
Planning Your Application Program 
(data) is the input value in engineering units of the 
specified channel of the specified analog input mod- 
ule. 
If (data)=” “, it means the channel is invalid. 
(dddd) is the input value in two’s complement format 
of the specified channel of the specified module. If 
(dddd)=” “, it means the channel is invalid. 
(cr) is the terminating character, carriage return (0Dh). 
Example  command: #01S3C2(cr) 
response: +9.750 (cr) The command requests the 
ADAM-5017H/5017UH module in slot 3 of the 
ADAM-5000/TCP system at address 01h to return 
the input value of channel 2. 
The analog   input module responds that the 
input value of channel 2 is +9.750. 
6-88 ADAM-5000/TCP User’s Manual 