Specifications
6
OPTIONS
NOTE: To access internal jumper options: 1) disconnect the unit from AC power 2) remove the top panel 3) lay the unit with the front
panel facing away 4) using needle-nose pliers, move the desired jumper straps as described below 5) replace the top panel.
75 Ohm Back-Termination: From the factory, Inputs 1~4 have 3.9k ohm ’back-termination’, which is appropriate for most applications.
However, internal jumpers allow selection of 75 ohm ’back-termination’, which is required only for specific video applications. To select 75
ohm ’back-termination’, move the Input 1~4 jumper straps (J102~J402) down one pin, to the "75 OHMS" position (see diagram below).
INPUT 1INPUT 2INPUT 3INPUT 4
HI-Z
75
OHMS
HI-Z
75
OHMS
HI-Z
75
OHMS
HI-Z
75
OHMS
BNC
jack
BNC
jack
BNC
jack
BNC
jack
RCA
jack
RCA
jack
RCA
jack
RCA
jack
J402 J302 J202 J102
Internal Infrared Receiver Bypass: An internal jumper allows the Internal Infrared Receiver to be bypassed. To bypass the Internal
Infrared Receiver, move the "INTERNAL RECV" jumper strap (J3) left one pin, to the "OUT" position (see diagram below).
J3
IR1
INTERNAL RECV
OUT IN
ON
IR
ERROR
Logic Inputs Pin Assignments: When controlling the VSX41 via logic outputs from an ADVANTAGE
®
AGII or DRC4+4, internal jumpers
allow VSX41 Logic Inputs to be assigned to corresponding pins for those products (refer to AGII & DRC4+4 manuals). To assign Logic
Input pins, move the "SOURCE SELECT" jumper straps (J2) to the desired Logic Input Pin Number positions (see diagram below).
J3
IR1
F1 F2
J1
C1
C2
INTERNAL RECV
OUT IN
ON
IR
ERROR
J2
948376261
12243
SOURCE SELECT
LOGIC INPUT PIN NUMBER
Remote Control Button Assignment: When using Remote Output to control additional ADVANTAGE products, VSX41 Channel Select
functions may be assigned to the next row of buttons, to avoid conflict with the other products. To assign Channel Select to the second
row of remote control buttons, move the "OPTION Z" jumper strap (J4) down one pin, to the "OFF" position (see diagram below).
ON
OFF
OPTION
z
J4