SETUP
LOGIC OUTPUT POLARITY SCREEN
Normally, when a Logic Output turns ‘on’ it provides a DC path to ground, which is then used to control ‘active-low’ type circuits. The Logic
Outputs Polarity screen simply allows this operation of the individual Logic Outputs to be reversed, for driving ‘active-high’ type circuits.
CONFIGURATION OPTIONS SCREEN
The Configuration Options screen is used to select options which customize the operation of the VRAM. At the top of the Configuration
Options screen, the Serial Number
and Firmware Version of the VRAM will be displayed. The PC Control Software can operate ‘off-line’
(with no product connected) by opening a ‘new’ file for the desired product. The Serial Number and Firmware Version are not displayed for
‘new’ (‘off-line’) files. Device Number
allows a device number (0~63) to be assigned to the currently active VRAM. This allows multiple
VRAM (or other ADVANTAGE
®
programmable products) to be individually controlled when linked together. Unique device numbers must
be assigned to each device before the devices are linked together. Device Name
allows a custom name to be given to the particular
VRAM, by entering up to 30 characters of text. The Device Name will be stored in the VRAM memory, and will be displayed on the title bar
of the Main screen whenever that VRAM is accessed with the software. Power-up Status
provides a choice of settings to be recalled from
non-volatile memory each time the VRAM is powered up When ‘pre-defined power-up preset’ is selected, the associated store & recall
preset options are then made available on the Mix screen, via the Store button menu. Baud Rate
determines the speed of data transfer for
the software, as well as for any products currently connected which support this function. Help
provides additional instruction. Close will
close the Configuration Options screen.