Specifications

– –
– –
54 55
My GUID
These registers contain the factory-programmed read-only GUID address.
This address is unique for each module and is used by all packet types as
a unique origination address.
Figure 65 shows the GUID Registers.
Release Number - NV Address = 0x78
This register contains a hard-coded release number corresponding to a
firmware version and hardware platform. Figure 66 shows examples of the
commands and Figure 67 lists current releases to date.
250 Series GUID Registers
Name
Non-Volatile
Address
Description
regMYGUID[3] 0x34 MSB of the GUID address
regMYGUID[2] 0x35 Byte 2 of the GUID address
regMYGUID[1] 0x36 Byte 1 of the GUID address
regMYGUID[0] 0x37 LSB of the GUID address
Figure 65: 250 Series GUID Registers
250 Series Release Number Register Settings
V1 Release Number
0x0D 1.0.5
0x10 1.0.5a
0x11 1.1.0
0x14 1.1.0 (Brazil)
Figure 66: 250 Series Transceiver Release Number Command and Response
Figure 67: 250 Series Transceiver Release Number Register Settings
250 Series Release Number
Read Command Read Response
Header Size Escape Address ACK Address Value
0xFF 0x02 0xFE 0x78 0x06 0x78 V1
As an example, if regAUTADD is set to 0x0F (Any Auto Address) and a
GUID packet is received from another module, then regAUTADD reads
back as 0x4F. The lower 4 bits indicate that the module is set to any auto
address (0xF). The upper 4 bits indicate that the packet that was just
received was a GUID Network Mode packet (0x4).
Figure 63 summarizes the configuration values for the lower 4 bits of the
register.
Figure 64 shows the Network Mode values that the module writes to the
upper 4 bits after successfully receiving a packet.
250 Series Auto Addressing Register Settings
Auto Address Value Meaning Action
0x00 Auto Addressing disabled
Destination Registers not
populated
0x04 GUID Auto Address
Auto-populates GUID Address
Destination Register Only
0x06 User Auto Address Mode
Auto-populates User Address
Destination Register
0x07
Extended User Auto Address
Mode
Auto-populates User Address
Destination Register
0x0F Any Auto Address Mode
Auto-populates GUID Address
Destination Register
Figure 63: 250 Series Transceiver Auto Addressing Register Settings
250 Series Auto Addressing Network Mode Indicator
Network Mode Meaning
0x4 GUID Networking Mode
0x6 User Networking Mode
0x7 Extended User Networking Mode