Service Manual
19
LCD displays “SENS H” ([PTT]: R/T, SCAN, wide/narrow)
(11).
Center Frequency with CTCSS 250.3 check
LCD displays “SENC 38” ([PTT]: R/T, SCAN, wide/narrow)
Operations: Press [UP]/[DOWN] to select the next menu option.
Press [PTT] to enter option settings:
In [1]-[7] options, LCD displays blinking digits. Now press [UP]/[DOWN] to adjust, press [MONI]
to exit.
In [8]-[11] options, C/L/H blinks, indicating center frequency, low frequency or high frequency. If
wideband, “F” is displayed; if narrowband, “Fn” is displayed.
Now press [MONI] to exit; press [SCAN] to switch the band between wide and narrow. Press
[UP]/[DOWN] to change power between high and low.
Note: Center, low and high frequency can be changed by PC programming software.
Keys combination set
Select “ASSIgn” in Power On menu. The radio will enter keys combination set mode.
1. Set [MONI]+[UP] valid/invalid. LCD displays UP on/oFF.
2. Set [MONI]+[Down] valid/invalid. LCD displays dn on/oFF.
3. Set [MONI]+[SCAN] valid/invalid. LCD displays SCN on/oFF.
4. Set [MONI]+[PTT] valid/invalid. LCD displays Ptt on/oFF.
Above keys combinations are valid only in user mode.
Operations:
Press [UP]/[DOWN] to toggle the keys combination between on and off.
Press [PTT] to save the setting and enter the next option setting.
Press [MONI] to exit the mode and return to “ASSIgn” option in Power On Menu.