User Manual
Epoch-S02-19002W RF Repeater
User Manual V1.3
Advanced RF Technologies, Inc. Proprietary Document Page 20 of 33
2.1.3.2 Alarm Setting Window
Control Item Action Downlink Uplink
Downlink/Uplink
RSSI Sets Low RSSI Alarm Level -120 ~ -30 dBm -120 ~ -30 dBm
Downlink/Uplink
Input Overload
Sets Input Overload Level -90 ~ -20 dBm -90 ~ -20 dBm
RSSI
The RSSI alarm is the minimum RSSI value that the Epoch-S02-19002W requires
to ensure optimal coverage. The RSSI alarm will go off when the RSSI is lower
than the threshold value (refer to the RSSI value in the Alarm Setting Window).
The threshold RSSI value can also be adjusted manually @ 0.5 dB step (range is
shown in Table 3 on page 19).
Input Overload
A
Downlink/Uplink Input Overload
alarm occurs when the input signal strength
to the Epoch-S02-19002W exceeds the threshold value (refer to the
Uplink/Downlink Input Overload
values in the Alarm Setting window).
Figure 8 - Alarm Setting Window of the Epoch-S02 OMS V4.XX
Table 3 - Alarm Threshold Values