User Manual
Epoch-III-P8024/8030/8037NM
User Manual V1.6
Advanced RF Technologies, Inc. Proprietary Document Page 23 of 41
3.3 Repeater Control
If you click on
Control tab, the following window will appear:
In this window, the user can adjust the following parameters:
General Setting
- Automatic Gain Control (Default mode is Off)
- Downlink HPA on/off (Default mode is On)
- Uplink HPA on/off (Default mode is On)
- Uplink Tracking Mode on/off (Default mode is Off)
Manual Gain Control
Î - Downlink Gain Control (40 to 80 dB @ 0.5 dB step)
Epoch-III-P8024NM: 40 to 80 dB @ 0.5 dB step, default value: 40 dB
Epoch-III-P8030/8037NM: 50 to 80 dB @ 0.5 dB step, default value: 50 dB
Î - Uplink Gain Control (40 to 80 dB @ 0.5 dB step)
Epoch-III-P8024NM: 40 to 80 dB @ 0.5 dB step, default value: 40 dB
Epoch-III-P8030/8037NM: 50 to 80 dB @ 0.5 dB step, default value: 50 dB
Î - Downlink AGC Level
Epoch-III-P8024NM: 0 to 24 dBm @ 0.5 dB step, default value: 24 dBm
Epoch-III-P8030NM: 0 to 30 dBm @ 0.5 dB step, default value: 30 dBm
Epoch-III-P8037NM: 0 to 37 dBm @ 0.5 dB step, default value: 37 dBm