User's Manual
Epoch-III-C9024/9030/9533
User Manual V0.1
Advanced RF Technologies, Inc. Proprietary Document Page 22 of 36
Parameters Range Step Size
DL/UL Output Power -10 ~ 24 dBm 0.1 dB
DL/UL Input Power -12 ~ -97 dBm 0.1 dB
Gain 50 ~ 90 dB 0.5 dB
- Alarm: Will display five alarms with three different status conditions (Normal,
Soft Fail or Hard Fail). ‘Under Current’, ‘Over Temperature’, and ‘VSWR at
Server’ are common alarms for Epoch-III-C9024/9030/9533 it self. But ‘RSSI
at donor’ and ‘RF Power’ are respective alarms for CDMA.
- Message Board (CDMA): Will show up to recent 20 log messages for
CDMA operation (alarms) & Heartbeats on the CDMA status window.
- Installation (CDMA): Will display CDMA repeater’s installation status (Not
Installed or Installed).
- Repeater Info: Will display the Epoch-III-C9024/9030/9533 serial number,
and location information (latitude and longitude coordinates).
- Repeater Location: Will display the address where the Epoch-III-
C9024/9030/9533 is installed.
- Technical Support: Will display ADRF’s technical support contact
information.
- Installer Contact Info: Will display the installer’s name, phone and e-mail
address.
Note: Once successfully logged in, the repeater model name and the site/cascade
ID will be displayed on the top of all the windows.
Table 2 – The displayed value ranges on the CDMA status.