Connectivity Issue Unable to Interface to repeater with GUI Software.
1. Please verify under Device Manager of
Windows that the necessary drivers for the USB
to serial adapter are installed.
2. Be sure to use the GUI software from the CD
that came with the repeater.
3. If for some reason the CD is not available,
contact 24HR tech support to acquire the
appropriate one.
4. In the event of using a USB-to-serial
converter, you must be sure to the COM port
number on the STATUS PAGE matches the
COM port number of the usb to- serial adapter
in your Device Manager of Windows.
5. If the GUI software at any time reports a
missing file error such as component
missing, please be sure to contact our tech
support staff directly at the number provided
below.
6. Connectivity is accomplished successfully
when both TX/RX lights are blinking green
in the lower right-hand corner of the GUI
software.
Connecting to DAS
All our PCS as well as Cellular BDAs can have the AGC function enabled
and the Downlink AGC Level set from 0dBm to whichever value is
specified by the manufacturer for common DAS applications.
PCS: lowest DL AGC value 0dBm
To get output power on the Downlink side of
the BDA even lower to plug into a DAS system,
the use of 5dB or 10dB attenuators/pads with
the proper tolerance of wattage is
recommended.
For any other issues, contact ADRF Tech Support at 1-800-313-9345 or 1-323-514-9070