User's Manual
Epoch-H (HP/HC) RF Repeater
User Manual V1.5
Advanced RF Technologies, Inc. Proprietary Document Page 29 of 60
ⓑ Manual Gain Control
- Downlink Gain Control (65 to 95 dB @ 0.5 dB step)
- Uplink Gain Control (65 to 95 dB @ 0.5 dB step)
- Downlink AGC Level
Epoch-H-5W: 10 to 37 dBm @ 0.5 dB step, default value: 37 dBm
Epoch-H-10W: 13 to 40 dBm @ 0.5 dB step, default value: 40 dBm
Epoch-H-20W: 16 to 43 dBm @ 0.5 dB step, default value: 43 dBm
- Uplink AGC Level
Epoch-H-5 / 10 / 20W: 0 to 27 dBm @ 0.5 dB step, default value: 27 dBm
ⓒ System
- If you click the Reboot button, the following message box will appear:
When the system reboots, the latest settings will be saved.
Please wait approximately 30 seconds to 1 minute for the system to reboot.
- If you click the Factory Setting button, the following message box will appear:
Factory setting will erase the saved settings by the user and change all the
parameters to the factory default settings.