User Manual
Epoch-HP RF Repeater
User Manual V1.1
Advanced RF Technologies, Inc. Proprietary Document Page 20 of 36
If
Uplink Tracking ON
is unchecked, then the user can set the AGC level in both
links.
Models Gain Range AGC Input Range
Epoch-HP-05/XX
(37 dBm or 5 W Model)
65 to 95 dB -58 to -28 dBm
Epoch-HP-10/XX
(40 dBm or 10 W Model)
65 to 95 dB -55 to -25 dBm
Epoch-HP-20/XX
(43 dBm or 20 W Model)
65 to 95 dB -52 to -22 dBm
Downlink/Uplink HPA Mode
The HPA mode enables the user to turn the HPA on or off. If the HPA is turned
off on either link, the Epoch-HP will not operate properly. Both HPAs needs to
be turned on for the RF portion of the repeater to work in both directions
(downlink and uplink). By default, the
Downlink/Uplink HPA ON
box is checked.
Either or both HPAs can be turned off for troubleshooting purposes during an
installation process.
Uplink Tracking/Offset Modes
Uplink tracking mode enables or disables the
Uplink Tracking ON
feature that
sets the gain in the uplink equaling to the gain in the downlink. The tracking
gain offset is the difference in the uplink and downlink gains. For example, if
the downlink gain is 80 dB, the
Uplink Tracking ON
is checked, and the
Uplink
Tracking Gain Offset
is set to 3 dB, the uplink gain would be 77 dB.
By default, the
Uplink Tracking ON
box is not checked. If it was checked, then
the default
Uplink Tracking Offset
is set to 3 dB. This means that the uplink gain
will track the down link gain and will be 3 dB less.
Control Item Action Setting Value
Uplink Tracking ON Set Uplink Tracking Mode ON or OFF
Uplink Tracking Offset Set Tracking Gain Offset 0 ~ 25 dB @ 0.5 dB step
Table 4 - Uplink Tracking Mode and Tracking Gain Offset Range
Table 3 – AGC Input Range