User Manual
Epoch-HP RF Repeater
User Manual V1.1
Advanced RF Technologies, Inc. Proprietary Document Page 18 of 36
3.1.2 Status Window
The Status Window is the monitoring window of the Epoch-H V1.X. This
window enables the user to monitor the status and settings of the Epoch-
HP. In other words, no parameters can be changed in the Status Window.
To change parameters, you will need to go to the Control Window.
Band
Will display filter bandwidth,
currently selected bands, center
downlink & uplink operating
frequencies.
Repeater Input
Indicates input
signal strength of
the repeater after
being amplified by
the donor antenna
[in dBm].
Repeater Output
The output of the
repeater [in dBm]
before being radiated
by the server antenna.
Repeater Gain
Indicates the gain
of the repeater
[in dB].
Alarm Button
The alarm button changes color
to the corresponding status of
the repeater: Green for normal
operation; Yellow for soft fail
alarm; and Red for hard fail
alarm. Click on the alarm
button for detailed information.
Message Board
The user will be able to see heartbeat messages
which are sent out recently. In addition, the user
will also be able to see any alarms that are
generated along with messages once the alarms are
cleared as well.
Status Bar
Displays the status of the repeater (e.g. Status
Window Loaded Properly, etc.) and transmit
(TX) & receive (RX) communication LEDs.
Figure 8 - Status Window of the Epoch-H V1.X
Installation
Will let you know if the
repeater is properly
installed.
Modem Connection
Will let you know if the
wireless modem is
connected to the repeater
Log File
History for the
heartbeats and alarms
generated from the
repeater and can be
saved as a text file.
Clear
Will clear the
Message Board.