• Downlink Signal Low: Allows the user to specify how low the signal can be before triggering a “Downlink
Signal Low” soft-fail alarm
• Downlink Signal Not Detected: Allows the user to specify how low the signal can be before triggering a
“Downlink Signal Not Detected” soft-fail alarm
• Downlink RF Power: Allows the user to set a maximum deviation value for the downlink RF power
- For example, if the input signal is -50 dBm and the gain is set to 60 dB, the expected output power should
be 10 dBm. If the Downlink RF Power alarm value is set to 6dB, then if the output power is below 4 dBm,
then this will trigger a soft-fail alarm
• VSWR Alarm ON: Allows the user to enable/disable the VSWR alarm check