Page | 33
Main Gain Control Range
Control Modules 25K 100K Large Note
Downlink Gain
- 50~80 60~90 65~95 0.5dB step, default:
Minimum Level
Uplink Gain
- 50~80 60~90 65~95 0.5dB step, default:
Minimum Level
Downlink AGC Level
LTE &
CELL
15 ~ -14 25 ~ -4 38 ~ 8 0.5dB step, default:
Maximum Level
PCS &
AWS
20 ~ -9 30 ~ 0 43 ~ 13 0.5dB step, default:
Maximum Level
Uplink AGC Level
LTE &
CELL
15 ~ -14 25 ~ -4 25 ~ -4 0.5dB step, default:
Maximum Level
PCS &
AWS
20 ~ -9 30 ~ 0 30 ~ 0 0.5dB step, default:
Maximum Level
Uplink Tracking
Offset
- 10 ~ 0 10 ~ 0 10 ~ 0 0.5dB step, default:
3dB
Oscillation & AGC time Control Range
Control Modules 25K 100K Large Note
Oscillation Period
time
- 1~3600sec 1~3600sec 1~3600sec 1sec step, default:
3600sec
AGC Check Time
- 0.1 ~ 1 sec 0.1 ~ 1 sec 0.1 ~ 1 sec Not use
AGC Attack Time
- 0.1 ~ 1 sec 0.1 ~ 1 sec 0.1 ~ 1 sec Not use
AGC Release Time
- 0.1 ~
3600sec
0.1 ~
3600sec
0.1 ~
3600sec
0.1 sec step, default:
0.1 sec
Alarm Control Range
Control Modules 25K 100K Large Note
Downlink Signal Low
Alarm
- -30~-90 -30~-90 -30~-90 0.5dB step, default: -
85dB
Downlink Signal not
Detect Alarm
- -80~-110 -80~-110 -80~-110 0.5dB step, default: -
85dB
Downlink RF Power
Alarm
- 0 ~ 10 0 ~ 10 0 ~ 10 0.5dB step, default:
6dB
Uplink RF Power
Alarm
- 0 ~ 10 0 ~ 10 0 ~ 10 0.5dB step, default:
6dB