User's Manual

Axiom Repeater
User Manual V0.3
Page | 32
Oscillation Check Setting
o Oscillation Check ON: Enables or disables oscillation check
o Periodic Time: Allows the use to specify how often the repeater runs the
oscillation check
AGC Control Time Setting
o AGC Check Time: The frequency at which the system checks the AGC level
o AGC Attack Time: Time it takes to lower the gain to match the AGC level
o AGC Release Time: Time it takes to raise the gain to match the AGC level
Manual Gain Control
o Downlink Gain: Allows the DL gain to be adjusted manually when AGC is OFF
o Uplink Gain: Allows the UL gain to be adjusted manually when AGC is OFF
o Downlink AGC Level: Allows the user to set the DL gain when AGC is enabled
o Uplink AGC Level: Allows the user to set the UL gain when AGC is enabled
o Uplink Tracking Offset: This offset value determines how many dB lower the
uplink gain value will be relative to the downlink gain value