User's Manual

Axiom Repeater
User Manual V0.3
Page | 13
Condition for Alarm Activation Repeater goes into oscillation
Following Alarm Activation The portion associated with the oscillation shuts down, and at
time of oscillation the defined procedure goes into effect
S/D (Shutdown)
Parameters Specifications
LED Normal Solid Green LED on
Hard fail Solid Red LED on
Condition for Alarm Activation Overpower, Oscillation
DL_CF (Donor circuitry failure)
Parameters Specifications
LED Normal Solid Green LED On
Hard fail Solid Red LED On
Condition for indication RFU Module Donor circuitry failure
DL_Low (Donor power too low)
Parameters Specifications
LED Normal Solid Green LED On
Hard fail Solid Red LED On
Condition for indication Donor input level under threshold
UL_CF (Coverage circuitry failure)
Parameters Specifications
LED Normal Solid Green LED On
Hard fail Solid Red LED On
Condition for indication RFU Module coverage circuitry failure
RSSI (DL RSSI LED bar)
Parameters Specifications
LED Input < -95dBm Zero (0) bar On
Input < -85dBm One (1) bar On
Input < -75dBm Two (2) bars On
Input < -65dBm Three (3) bars On
Input < -55dBm Four (4) bars On
Input > -55dBm Five (5) bars On
3.1.3 Alarms
Parameters Remark
Tamper Temper detected
AC fail Power supply out of range
DC fail Power supply out of range
Communication failure Internal Communication failure
RMF Field replaceable module failure
RESET Reset alarm
Heartbeat Heartbeat
OSC Oscillation detected
UL RSSI fail Power at coverage port too high
UL PLL fail UL Synthesizer failure
H/W fail Hardware failure
S/W fail Software failure
UL Emission fail UL Out-of-band emissions out of spec
DL RSSI fail Donor Power too high/low