User's Manual

Axiom Repeater
User Manual V0.3
Page | 12
3.1.2 RFU LEDs
Axiom has LEDs on the front panel of the repeater as shown below in Figure 2.
Figure 2: RFU LED
PWR (RFU Power)
Parameters Specifications
LED Normal Blinking Green LED
Alarm Solid Red LED on
Condition for Alarm Activation Power fail
O/P (Over Power)
Parameters Specifications
LED
Normal Solid Green LED On
Soft fail Blinking Red LED
Hard fail Solid Red LED On
Condition for
Alarm
Activation
Soft fail Max power +1 <measured output < max power+2
Hard fail measured output > max power + 2
Following
Alarm
Activation
Soft fail
Only the alarm is activated and the repeater operates as normal
Hard fail
The function associated with the alarm shutdown, and the
shutdown process goes into effect
Manual
Parameters Specifications
LED
Manually HPA
Off/On
PCS (Cellular) Green LED On
Factory set or
Reboot
PCS (Cellular) Green LED Off
BITF (Built-in test failure)
Parameters Specifications
LED Normal Solid Green LED on
Hard fail Solid Red LED on
Condition for indication RFU Module built-in test failure
RMF (Replaceable module failure)
Parameters Specifications
LED Normal Solid Green LED On
Hard fail Solid Red LED On
Condition for indication RFU Module failure
AGC (AGC active)
Parameters Specifications
LED
AGC On Solid Green LED On
AGC Off LED Off
OSC (Oscillation detected)
Parameters Specifications
LED Normal Solid Green LED On
Hard fail Solid Red LED On