3. Go under ‘Control’ tab and turn off AGC and
change gain manually to verify BDA is
responding to changes. Recheck the measured
values.
Signal Low Soft Fail
Downlink Input Value is less than threshold:
PCS / Cell: -80dBm minimum
1. Ensure proper ports are connected (Donor/
Server).
2. Verify the Donor antenna is pointed toward
the correct cell site.
3. Verify the selected band(s) and be sure it is
the right band(s) for the area.
4. Please be aware that our BDA typically
require well above -85dBm (threshold) of
incoming RSSI on the DL side.
Under/Over
Current
Soft Fail
Current falls out of the permitted range
1. Factory Setting & Reboot
2. Recheck, if continues, contact Tech Support.
Hard Fail
Over
Temperature
Soft Fail
Repeater’s internal temperature exceeds the permitted range
1. Factory Setting & Reboot
2. Recheck, if continues, contact Tech Support.
Hard Fail
Input Overload Hard Fail
Input Signal Level increases beyond the set range:
PCS/ Cell: -30dBm max input
1. Add attenuator to donor/server antenna
(Applicable to DAS)
2. Factory Setting & Reboot
Low Isolation
Oscillation
Antennas are located too close to one another, causing RF output to feed
input.
1. Check Input Level. (fluctuates drastically)
2. We recommend 13~15dB + max gain of
repeater between the donor and the server
antenna as an isolation value.
3. Check antenna direction (make sure that the
Donor and Server antennas are not facing
one another)
4. Placing an attenuator before the nearest
serving antenna can also help to increase
isolation.