User's Manual
AEON-9030 RF Repeater
User Manual V1.0
Advanced RF Technologies, Inc. Proprietary Document Page 14 of 51
OVER POWER LED
Parameters Specifications
LED
Normal LED off
Soft fail PCS/ Cellular Green LED on
Hard fail PCS/ Cellular Red LED on
Condition
for Alarm
Activation
Soft fail
Max power +1 <measured output < max
power+2
Hard fail measured output > max power + 2
Following
Alarm
Activation
Soft fail
Only the alarm is activated and the repeater
operates as normal
Hard fail
The function associated with the alarm shuts
down, and the shutdown process goes into
effect
AGC LED
Parameters Specifications
LED
AGC On PCS / Cellular Green LED On
AGC Off PCS / Cellular LED Off
OSC LED
Parameters Specifications
LED
Normal LED off
Hard fail Red LED on
Condition for Alarm
Activation
Repeater goes into oscillation
Following Alarm
Activation
The portion associated with the oscillation
shuts down, and at time of oscillation the
defined procedure goes into effect
MANUAL LED
Parameters Specifications
LED
Manually
HPA Off/On
PCS / Cellular Green LED On
Factory set or
Reboot
PCS / Cellular Green LED Off
RSSI LED BAR
Parameters Specifications
LED
Input < -75dBm PCS / Cellular All LED Off
Input < -65dBm PCS / Cellular one LED On
Input < -55dBm PCS / Cellular two LED On
Input < -45dBm PCS / Cellular three LED On
Input < -35dBm PCS / Cellular four LED On
Input > -25dBm PCS / Cellular five LED On