User's Manual

(WKH UQHW3RUW
The Ethernet port can be used to communicate directly with the ADX DAS using a RJ-45 crossover
cable or can also be used to connect the ADX DAS to an external modem box.
)LJXUH (WKHUQHW3RUW
+ RVW5HPRWH6ZLWFK
The Host/Remote Switch allows the user to switch the default Repeater IP, Subnet Mask, and
Gateway of the repeater to an alternative setup. These settings can be adjusting by logging into the ADX
DAS in HOST mode and configuring the settings under the Modem Box Setting section on the Install
Page of NMS.
Once the settings are set, flipping the switch to the REMOTE position will reboot NMS module with
the new alternate settings. Please note that when the NMS is set to the REMOTE position, DHCP is
disabled and the NMS will not automatically assign an IP address to any device that connects directly to
the NMS.
)LJXUH +RVW5HPRWH6ZLWFK
x Host IP: 192.168.63.1 (Fixed IP, unable to modify this IP address)
x Remote IP: 192.168.63.5 (Default IP, but can be modified in Host mode)
 +(9LHZ589LHZ6ZLWFK
The HE View/RU View Switch allows the user to be able to disable periodic monitoring operated by
NMS. In the HE view mode, NMS monitors the status of all subordinate units connected to NMS
periodically but when switched to RU view the NMS does not monitor the subordinate units. When the
user goes to a RU and wants to monitor/control the HE, the user should set the NMS as RU view mode
before going to the RU. If not, there might be some data collisions between the NMS and RU, which may
prevent the user from properly monitoring or configuring the HE when at the RU. Consequently, the user
should set as HE view mode when the user is at the HE and should set as RU view mode when the user
is at the RU.
)LJXUH +(9LHZ589LHZ6ZLWFK