User Manual
Epoch-M1C RF Repeater
User Manual V1.1
Advanced RF Technologies, Inc. Proprietary Document Page 27 of 38
2.3.2 Downlink/Uplink Alarms
Alarm List Soft Fail Hard Fail Remark
RSSI O -
Input Power Overload O -
Downlink
(Forward)
Over Power* O O
RSSI O -
Input Power Overload O -
Uplink
(Reverse)
Over Power* O O
Alarms will turn on if the
value is not within operable
limits specified in the
Control Alarm Setting
Window.
Note: The Over Power
parameter is fixed and
cannot be modified by
the user.
The example below distinguishes the difference between an over power soft
failure and an over power hard failure:
If the threshold value for the downlink over power parameter is set to 22.0 dBm
(factory set value), a Hard Fail alarm would occur if the downlink over power
value was greater than 22.0 dBm (20 dBm is the maximum composite power
allowable). Similarly, a Soft Fail alarm would occur if the downlink over power
value was greater than 21.0 dBm but less than 22.0 dBm. Vice versa, the same
example is also applicable in the uplink side.
2.4 Default Control Settings
2.4.1 Default General Settings
Control Item Setting Value
AGC Mode ON
Downlink/Uplink HPA Mode
ON
Uplink Tracking Mode ON
Downlink/Uplink Gain 70 dB
Downlink/Uplink AGC Level 20 dBm
Tracking Gain Offset 3 dB
a. When
Uplink Tracking ON
mode is enabled, the
Tracking Gain Offset
is
set to 3 dB.
b. When
AGC ON
mode
is enabled, by default the
Downlink/Uplink AGC
Level
is set to 20 dBm.
Table 8 – List of Alarm Settings of the Epoch-M1C Software
Table 9 - Adjustable Alarm Settings of the Epoch-M1C Epoch-M1C