User's Manual

Epoch-M1P RF Repeater
User Manual V1.0
2.4.2 Default Alarm Setting
Setting Value
Control Item
Downlink Uplink
RSSI -95 dBm -110 dBm
Input Overload -35 dBm -35 dBm
Heartbeat On/Off ON
Heartbeat Time 20 minutes
Table 10 - Default Alarm Parameter Values of the Epoch-M1P Software
3 Maintenance Guide for Epoch-M1P
3.1 Periodic Inspection Checklist
a. Check for loose connections to the repeater and antennas. If connections
are loose, make sure that all connections are tightly fastened properly.
b. Cables and connectors are in good condition.
c. Ensure that the repeater brackets are in good condition and that the
repeater is securely fastened.
3.2 Preventive Measures for Optimal Operation
3.2.1
s
3.2.2
Recommendations
Perform the
Periodic In pection Checklist
quarterly or semiannually.
Precautions
Do not operate the repeater with the antennas in extremely close
proximity as this may cause damage to the repeater.
Do not change parameters unless instructed to do so by an authorized
supervisor.
Do not move the repeater unless instructed to do so by an authorized
supervisor.
Do not detach any cables to the repeater unless repair of respective
components are necessary.
Advanced RF Technologies, Inc. Proprietary Document Page 28 of 38