Epoch-M1P RF Repeater
User Manual V1.0
Figure 13 - All Alarm Parameters Supported by Epoch-M1P
In the event of a hard fail alarm, the control board will shutdown the HPA (both
uplink & downlink) for 30 seconds and then turns on the HPA to check for a
repeated hard fail occurrence. If the hard fail alarm is persisting up to four
consecutive occurrences, the control board will shutdown the HPA for 20 minutes
(total of five consecutive hard fails). After 20 minutes, the HPA will automatically
come back alive and the control board will check if the Hard Fail alarm has cleared.
If it has not, the same process will continue as mentioned above.
** The alarms can also be viewed on the front panel of the repeater by clicking
the VFD button. Please refer to Appendix B for more detailed information.
rt r r t) f r t
2.3.1
** Epoch-M1P also suppo s AAI (Auxilia y Ala m Inpu . Please re e to Sec ion
1.1.2 on Page 6.
General (Fixed Parameter) Alarms
Alarm List Soft Fail Hard Fail Comments
Over/Under Current O O
Soft Fail: Less than 0.5 A @ under current
Hard Fail: More than 4.7 A @ over current
Over Temperature O O
Soft Fail: 158 ~ 185 °F
Hard Fail: > 185 °F
Synthesizer Lock - O Band selection will not work properly
VSWR - O > 1.5:1
RF Power - O
Will occur in the event of any
Hard Fail alarm
Table 7 - General (Fixed Parameter) Alarms of the Epoch-M1P Software
Advanced RF Technologies, Inc. Proprietary Document Page 26 of 38