User's Manual

Epoch-M1P RF Repeater
User Manual V1.0
If there’s a modem inside the repeater, you don’t need to set the date and time
manually.
Alarm Setting
RSSI
The RSSI alarm is the minimum RSSI value that the Epoch-M1P requires to ensure
optimal coverage. The RSSI alarm will go off when the RSSI is lower than the
threshold value (refer to the RSSI value in the Alarm Setting Window). The
threshold RSSI value can also be adjusted manually @ 0.5 dB step (range is
shown in Table 5 on page 20).
Input Overload
A Downlink/Uplink Input Overload alarm occurs when the input signal strength
to the Epoch-M1P exceeds the threshold value (refer to the Uplink/Downlink
Input
Overload values in the Alarm Setting window).
Control Item Action Downlink Uplink
Downlink/Uplink RSSI Sets Low RSSI Alarm Level -110 ~ -80 dBm -110 ~ -80 dBm
Downlink/Uplink
Input Overload
Sets Input Overload Level -45 ~ -20 dBm -45 ~ -20 dBm
Table 5 - Alarm Threshold Values
2.1.4 Install Window
At the time of installation, the installer needs to go to the Install Window of the
Epoch-M1P Software. The Install Window will guide the installer through a step
by step process to properly install the Epoch-M1P repeater.
For setup or installation of Epoch-M1P, go to the Install
Window.