User's Manual

Epoch-M1P RF Repeater
User Manual V1.0
2.1.3.2 Alarm Setting Window
Figure 8 - Alarm Setting Window of the Epoch-M1P Software
Heartbeat
Heartbeat is a periodic message sent out to Wireless Provider’s NOC
only if the
repeater comes with a wireless modem
.
Control Item Action Setting Value
Heartbeat ON/OFF Set Heartbeat Mode ON/OFF
Periodic Time Set Heartbeat Time 1 ~ 60 min @ 1 min step
Table 4 - Heartbeat Mode and Time Ran
g
e
Heartbeat Mode
The Heartbeat ON box is checked by default.
The heartbeat feature is only
available if the repeater has a wireless modem.
Periodic Time
The
Periodi Time
is the time interval between Heartbeats
only if the repeater
has a wireless modem connected to it
. The default periodic time is 20 minutes.
The periodic time can be adjusted manually between 1 to 60 minutes.
c
Date & Time
If the repeater doesn’t come have a wireless modem, you need to set the date
and time manually in order for the Log File to reflect accurate information in
terms of when the data was generated.
Advanced RF Technologies, Inc. Proprietary Document Page 19 of 38