User's Manual
Table Of Contents
- Installation Guide for Epoch-S02
- Environmental requirements
- Warnings and Hazards
- Tools and Recommendations for Installation
- Epoch-S02 Parts List
- Step by Step Instructions for Installation
- User Manual V1.1 using OMS V4.01
- Menu Structure
- Using the Epoch-S02 OMS V4.01
- Alarms
- Default Control Settings
- Maintenance Guide for Epoch-S02 OMS V4.01
- Periodic Inspection Checklist
- Preventive Measures for Optimal Operation
- Troubleshooting
- Epoch-S02 OMS V4.01 Scenarios
- Heartbeat Scenarios
- Warranty and Repair Policy
- General Warranty
- Specific Product Warranty Instructions
- A.1 Minimum Requirements
- A.2 Epoch-S02 OMS V4.01 Installation/Startup
- Appendix B: Specifications
Epoch-S02 RF Repeater
User Manual V1.1
MECHANICAL SPECIFICATIONS
PARAMETERS SPECIFICATIONS COMMENTS
Cabinet Size 15.75 x 17.72 x 7.85
inches
W x H x D
Cabinet Weight ≤ 50 lbs
Cabinet Mount Type Utility Pole Mount
Antenna N-Type (F)
Coupling SMA (F) 30 dB
Frame Ground Hex Nut (M6)
Connector
Type
Control DB9 (M)
Cooling Convection
Weatherproofing NEMA 4, IP65
POWER SPECIFICATIONS
PARAMETERS SPECIFICATIONS COMMENTS
Main AC Power 100 to 240 VAC
AC Frequency 45 to 65 Hz
Power Consumption ≤ 300 Watts
AC Supply Protection Fuse
Output Voltage 12.0 VDC
Endurance ≥ 2 hour
Main to
Auxiliary
Automatic
Auxiliary to
Main
Automatic
Auxiliary
Power
(Option)
Battery
Protection
Internal Fuse
Grounding External Threaded Stud
ENVIRONMENTAL SPECIFICATIONS
PARAMETERS SPECIFICATIONS COMMENTS
Operating Temperature -22 ˚F to +122 ˚F
Storage Temperature -22 ˚F to +176 ˚F
Humidity 10 to 85%, RH
Advanced RF Technologies, Inc. Proprietary Document Page 31 of 31