User's Manual

Epoch-S02 RF Repeater
User Manual V1.1
3.2.2 Precautions
Do not operate the repeater with the antennas in extremely close
proximity as this may cause damage to the repeater.
Do not shut down the repeater unless absolutely necessary (in the case
where the repeater is a hazard to safety).
Do not change parameters unless instructed to do so by an authorized
supervisor.
Do not move the repeater unless instructed to do so by an authorized
supervisor.
Do not detach any cables to the repeater unless repair of respective
components are necessary.
4 Troubleshooting
4.1 Epoch-S02 OMS V4.01 Scenarios
Tx Rx Explanation
RED RED
The COM Port can not send or receive data. Check the COM
port connection to the computer and the Repeater. Ensure
that the Repeater is on and that the connection to the repeater
is secure.
Blinking
GREEN
RED
The Repeater is not receiving any commands from the OMS
software. Ensure that the Repeater is on.
Blinking
GREEN
GREEN
The Repeater is not receiving any commands from the OMS
software. Ensure that the Repeater is on and that the
connection to the repeater is secure.
Blinking
GREEN
Blinking
GREEN
Successful Connection. The OMS V4.01 and the Repeater are
communicating successfully.
Table 4.1 Tx and Rx LEDs
Note: The Tx/Rx LEDs will blink periodically only on the main status window.
4.2 Heartbeat Scenarios
If the Heartbeat of the Epoch-S02 is not being received by the NOC, it may be
necessary to send a technician to visit the Epoch-S02 site. Scenarios for no
Advanced RF Technologies, Inc. Proprietary Document Page 26 of 31