User's Manual

Epoch-S02 RF Repeater
User Manual V1.1
2.4.2 Default Alarm Setting
Setting Value
Control Item
Downlink Uplink
RF Total Power 10 dB --
RSSI -95 dBm -110 dBm
Input Overload -30 dBm -30 dBm
Heartbeat On/Off ON
Heartbeat Time 20 minutes
Table 2.4.2 Default Alarm Parameter Values of the
Epoch-S02 OMS V4.01
3 Maintenance Guide for Epoch-S02 OMS V4.01
3.1 Periodic Inspection Checklist
1. Ensure that the door is closed and locked before inspection.
2. Check for loose connections to the repeater and antennas. If connections
are loose, make sure that all connections are tightly fastened properly.
3. Cables and Connectors are in good condition.
4. Open the Repeater door to check that the Repeater is on.
5. Check that all components inside are intact with no unusual wear (e.g., rust,
dirt, etc.).
6. Ensure that the Repeater brackets (if used) are in good condition and that
the Repeater is securely fastened.
3.2 Preventive Measures for Optimal Operation
3.2.1 Recommendations
Perform the Periodic Inspection Checklist quarterly or semiannually.
Always lock the door to the repeater to prevent unauthorized access.
Tune the Repeater so that amplification is only within the band selected.
In other words, no amplification of unwanted signal(s) outside the
selected band.
Advanced RF Technologies, Inc. Proprietary Document Page 25 of 31