User's Manual
Table Of Contents
- Installation Guide for Epoch-S02
- Environmental requirements
- Warnings and Hazards
- Tools and Recommendations for Installation
- Epoch-S02 Parts List
- Step by Step Instructions for Installation
- User Manual V1.1 using OMS V4.01
- Menu Structure
- Using the Epoch-S02 OMS V4.01
- Alarms
- Default Control Settings
- Maintenance Guide for Epoch-S02 OMS V4.01
- Periodic Inspection Checklist
- Preventive Measures for Optimal Operation
- Troubleshooting
- Epoch-S02 OMS V4.01 Scenarios
- Heartbeat Scenarios
- Warranty and Repair Policy
- General Warranty
- Specific Product Warranty Instructions
- A.1 Minimum Requirements
- A.2 Epoch-S02 OMS V4.01 Installation/Startup
- Appendix B: Specifications
Epoch-S02 RF Repeater
User Manual V1.1
Figure 2.3 All Alarm Parameters from the Main Status
Window of the Epoch-S02 OMS V2.0
In the event of a Hard Failure, the control board will shutdown the HPA for 30
seconds and then turns on the HPA to check for a repeated Hard Fail occurrence. If
the next two occurrences sense a Hard Fail, the control boards will shutdown the
HPA for 1 hour (total of three consecutive hard fails). After 1 hour, the HPA will
automatically come back alive and the control board will check if the Hard Fail alarm
has cleared or not. If it has not, the same process will continue as mentioned above.
2.3.1 General (Fixed Parameter) Alarms
Alarm List Soft Fail Hard Fail Comments
Over/Under Current O O
Soft Fail: Less than 1 A @ under current
Hard Fail: More than 6 A @ over current
Over Temperature O O
Soft Fail: < 158 ~ 185 °F
Hard Fail: > 185 °F
Synthesizer Lock - O Synthesizer Unlock
VSWR - O > 1.5:1
Low Isolation/Osc. - O Repeater oscillation
Table 2.3.1 General (Fixed Parameter) Alarms of the OMS V4.01
Advanced RF Technologies, Inc. Proprietary Document Page 23 of 31