User's Manual

16
3. Dip-Switch Settings
There are six dip-switches located on the decoder board, which is one dip-switch per motion or
push button pair (1 dip-switch per left and right push button).
Fig. 10
Dip Settings
Relay Functions
# of Relays
Used
0000001 Closed/Closed Relay Action at 2
nd
Speed 4
0000010 Closed/Closed Relay Action at 2
nd
Speed 3
0000011 Opened/Closed Relay Action at 2
nd
Speed 4
0000100 F/FR2 Relay Action at 2
nd
Speed 4
0000101 F/FR1/FR2 Relay Action at 2
nd
Speed 4
0000110 On/Off 2
0000111 Magnet On/Off 2
0010001 Closed/Closed Relay Action + External Warning 4
0010010 Closed / Closed Relay Action + External Warning 3
0010011 Opened/Closed Relay Action + External Warning 4
0010100 F/FR2 Relay Action + External Warning 4
0010101 F/FR1/FR2 Relay Action + External Warning 4
0100001 Closed/Closed + Brake 4
0100010 Closed/Closed Relay Action + Brake 3
0100011 Opened/Closed Relay Action + Brake 4
0100100 F/FR2 Relay Action + Brake 4
0100101 F/FR1/FR2 Relay Action + Brake 4
0110001 Closed/Closed Relay Action + Brake + External Warning 4
0110010 Closed/Closed Relay Action + Brake + External Warning 3
0110011 Opened/Closed Relay Action + Brake + External Warning 4
0110100 F/FR2 Relay Action + Brake + External Warning 4
0110101 F/FR1/FR2 Relay Action + Brake + External Warning 4