User's Manual
FLEX MINI System Instruction Manual
January 2014
10 of 16
71 423 56 8
ON
12345678
ON
12345678
2.2 RECEIVER
2.2.1 Dipswitch Setting
Top position → “1”
Bottom position → “0”
Dipswitch #1 (right):
Position Dip 1 Dip 2 Dip 3 Dip 4 Dip 5 Dip 6 Dip 7 Dip 8
Set to “0”
PB1
Normal
PB2
Normal
PB3
Normal
PB4
Normal
PB5
Normal
PB6
Normal
PB7
Normal
PB8
Normal
Set to “1”
PB1
Toggled
PB2
Toggled
PB3
Toggled
PB4
Toggled
PB5
Toggled
PB6
Toggled
PB7
Toggled
PB8
Toggled
Dipswitch #2 (left):
Position Dip 1 Dip 2 Dip 3 Dip 4 Dip 5 Dip 6 Dip 7 Dip 8
Set to “1”
PB1&2
On & Off
PB3&4
On & Off
PB5&6
On & Off
PB7&8
On & Off
PB1&2
Interlocked
PB3&4
Interlocked
PB5&6
Interlocked
PB7&8
Interlocked
Set to “0”: According to Dip-switch #1 setting
Dip 5~8 set to “1”: Pushbutton pair interlocked. When set to interlocked pair you must reconfigure dipswitch #1 below
Dipswitch #1 (right):
Position Dip 1&2 Dip 3&4 Dip 5&6 Dip 7&8
Set to “00”
PB1&2 Normal/Normal
Interlocked
PB3&4 Normal/Normal
Interlocked
PB5&6 Normal/Normal
Interlocked
PB7&8 Normal/Normal
Interlocked
Set to “01”
PB1&2 Toggled/Toggled
Interlocked
PB3&4 Toggled/Toggled
Interlocked
PB5&6 Toggled/Toggled
Interlocked
PB7&8 Toggled/Toggled
Interlocked
2.2.2 Fuse Ratings
Fuse # 250VAC
F2 & F3 5.0A
F1 0.5A