User's Manual
Flex 4ES/EX Instruction Manual
September 2016
Page 26 of 37
4.2.5. Fuse Ratings
FUSE # 110~120VAC 220~240VAC 380~400VAC 410~460VAC 24VAC
42 &
48VAC
9~36VDC
F3 ~ F10
5.0A 5.0A 5.0A 5.0A 5.0A 5.0A 5.0A
F1 ~ F2
0.5A 0.5A 0.5A 0.5A 1.0A 1.0A 2.0A
4.2.6. Indicator Light and Buzzer Installation
The miniature indicator light and buzzer can be easily fitted
onto the receiver enclosure. The indicator light or the buzzer
works simultaneously with the receiver MAIN relays
(manufacture preset). When receiver MAIN relays are
activated the indicator light or the buzzer is also activated, or
vise versa. Make sure the indicator light or the buzzer is
connected to the K30 Function output relay CN11 port
located on the AC line filter/relay board inside the receiver.
Please contact ARC representative if you would like the
indicator light or the buzzer work differently than described
above.
4.2.7. Other Function Output Relays Settings
Listed below are other types of functions that can be outputted through the three Function output
relays (K25, K26 and K30) via the infrared IR programmer unit. Please contact ARC
representative for more details.
LV : Function relay closes when receiver voltage is low.
ID : Function relay works simultaneously with all motion commands.
NORMAL : START function + AUX with normal momentary output.
TOGGLE : START function + AUX with toggled/latching output.
TOG&E : START function + AUX with toggled/latching output. The relay opens when
STOP button is pressed down and transmitter power off.
S/P : Function relay closes when START command is executed and opens only when
transmitter power is turned off.
EXT : Function relay works simultaneously with the receiver MAIN relays.
TDM A+B : Function relay closes when selector switch is rotated to the A+B position
and opens when rotate to A or B positions (tandem monitoring output).
HORN : Function relay closes for up to 3 seconds when START command is executed at
transmitter power on and then becomes a normal momentary output thereafter.
G SENSOR : Function relay closes when Zero-G sensor is triggered (receiver MAIN relays
deactivated) and opens when receiver MAIN relays are reactivated.