User's Manual
Flex 4ES/EX Instruction Manual
September 2016
Page 20 of 37
F1 F/R2R1 R1F1 F/R2
F1 R1 F2 R2R2F2R1F1
R2F2R1F1 R2F2R1F1
Fwd Rev
Slow
FastFwd Rev
Slow
Fast
4.2.2.2. Output Relay Actions at 2
nd
Speed (Flex 4EX only)
1. 3 output relays configuration with Closed/Closed contact at 2
nd
speed
F1 (or R1) output relay closed at 1
st
speed and F1 + F/R2 (or R1 + F/R2) output
relays closed at 2
nd
speed. Refer to section 4.2.3.1 on how to set to this function.
Forward 1
st
speed pushbutton pressed Forward 2
nd
speed pushbutton pressed
2. 4 output relays configuration with Opened/Closed contact at 2
nd
speed
F1 (or R1) output relay closed at 1
st
speed and F2 (or R2) output relay closed at 2
nd
speed. Refer to section 4.2.3.1 on how to set to this function.
Forward 1
st
speed pushbutton pressed Forward 2
nd
speed pushbutton pressed
3. 4 output relays configuration with Closed/Closed contact at 2
nd
speed
F1 (or R1) output relay closed at 1
st
speed and F1 + F2 (or R1 + R2) output relays
closed at 2
nd
speed. Refer to section 4.2.3.1 on how to set to this function.
Forward 1
st
speed pushbutton pressed Forward 2
nd
speed pushbutton pressed
4. 4 output relays configuration with Slow and Fast output relays (Type A)
Fwd (or Rev) + Slow output relays closed at 1
st
speed and Fwd (or Rev) + Fast output relays
closed at 2
nd
speed. Refer to section 4.2.3.1 on how to set to this function.
Forward 1
st
speed pushbutton pressed Forward 2
nd
speed pushbutton pressed