User's Manual

Flex 6ES/EX Instruction Manual
September 2016
Page 26 of 37
TOG&E : START function + AUX with toggled/latching output. The relay opens when
STOP button is pressed down and transmitter power off.
S/P : Function relay closes when START command is executed and opens only when
transmitter power is turned off.
EXT : Function relay works simultaneously with the receiver MAIN relays.
TDM A+B : Function relay closes when selector switch is rotated to the A+B position
and opens when rotate to A or B positions (tandem monitoring output).
HORN : Function relay closes for up to 3 seconds when START command is executed at
transmitter power on and then becomes a normal momentary output thereafter.
G SENSOR : Function relay closes when Zero-G sensor is triggered (receiver MAIN relays
deactivated) and opens when receiver MAIN relays are reactivated.