User's Manual
Flex 6ES/EX Instruction Manual
September 2016
Page 25 of 37
4.2.4. Jumper Settings
Jumper setting applies to functions such as the standard or
reversed logic A/B selector sequence, firmware version, system
testing and remote pairing methods.
Jumper Settings Function
JP3
(Opened)
Standard A/B selector sequence - Output
relay A activated at A position, output relay B activated at B position,
both relays activated at A+B position.
JP3
(Inserted)
Reversed logic A/B selector sequence - Output
relay B activated at A position, output relay A activated at B position,
both relays deactivated at A+B position.
JP6
(Inserted)
Display system firmware version
JP7
(Inserted)
For system testing only (receiver MAIN relays disabled)
JP8
(Opened)
Receiver-to-transmitter remote pairing
(pressing the Pairing button required)
JP8
(Inserted)
Receiver-to-transmitter remote pairing
(pressing the Pairing button not required)
4.2.5. Fuse Ratings
FUSE # 110~120VAC 220~240VAC 380~400VAC 410~460VAC 24VAC
42 &
48VAC
9~36VDC
F3 ~ F10
5.0A 5.0A 5.0A 5.0A 5.0A 5.0A 5.0A
F1 ~ F2
0.5A 0.5A 0.5A 0.5A 1.0A 1.0A 2.0A
4.2.6. Other Function Output Relays Settings
Listed below are other types of functions that can be outputted through the K25 Function output
relay via the infrared IR programmer unit. Please contact ARC representative for more details.
LV : Function relay closes when receiver voltage is low.
ID : Function relay works simultaneously with all motion commands.
NORMAL : START function + AUX with normal momentary output.
TOGGLE : START function + AUX with toggled/latching output.