User's Manual
Page 27
b. Non-Interlocked Functions
Contrary to interlocked settings, non-interlocked settings allow the two adjacent push buttons be
used simultaneously at the same time. Non-interlocked settings are usually applied to crane’s
auxiliary functions such as lights, horn, 3
rd
speed, auxiliary stop and Pitch & Catch. Each
dip-switch on the decoder module corresponds to one (1) motion or two (2) adjacent push
buttons (left & right push buttons).
Function
Code
Dip
Position
Setting
#1
Dip Position Setting
#2 ~ #4 (left button)
&
#5 ~ #7 (right button)
Function Description
A 1 000
Normal (momentary) contact
B 1 001
Toggled (latching) contact
C 1 010
Acceleration (3
rd
speed)
D 1 100
Normal + Start function. For added safety,
you must first rotate and hold the power key
switch at “START” position and then press
the intended push button at the same
time to activate the output relay.
E 1 110
Pitch & Catch
F 1 111
Auxiliary Stop
Example #1: Left button (set to function code A) / right button (set to function code A) → 1 000 000
Example #2: Left button (set to function code B) / right button (set to function code B) → 1 001 001
Example #3: Left button (set to function code A) / right button (set to function code C) → 1 000 010
Example #4: Left button (set to function code F) / right button (set to function code A) → 1 111 000
! When set to Pitch & Catch function make sure the 2
nd
transmitter is set to the next upper channel. For example, if the
system is preset at Ch.01 then the 2
nd
transmitter should be set to Ch.02. Furthermore, you must also set the dip-switch on
the receiving module (position #7 & #8) to “10” position (2-channel scanning), please refer to page 25.
!! When set to “Auxiliary Stop” do make sure that JP3 is inserted (refer to jumper settings next page).