User's Manual
Flex ECO 4S/4X/8S/8X/12S/12X Instruction Manual
April 2015
Page 22 of 36
4.2.3 Dipswitch Settings
4.2.3.1 Interlocked Pushbutton Pair
Interlocked means the pushbutton pair
can not be activated at the same time,
as it will cancel each other out.
Interlocked settings are usually applied
to electric motors with forward/reverse
motion and On & Off switches. Each
dipswitch on the RF/decoder board
corresponds to a pushbutton pair.
Dip
Settings
Function Descriptions
# of Relays
Used
00000000
Single speed
(F2, R2 and F/R2 relays not used)
2
00000010
Closed / Closed relay action at 2
nd
speed
(separate 2
nd
speed relay)
4
00000100
Closed / Closed relay action at 2
nd
speed
(shared 2
nd
speed relay)
3
00000110
Opened / Closed relay action at 2
nd
speed
(separate 2
nd
speed relay)
4
00001100 On (right button) & Off (left button) 2
00010010
On + Start / Off + Start - For added safety, you must first
press and hold the START button and then press the
On or Off pushbutton to activate the output relay.
2
00001110 Magnet Left On & Off 2
00010100 FWD / REV toggled (latching) 2
00100000 Single speed + External Warning* 2
00100010 Closed / Closed relay action + External Warning* 4
00100100 Closed / Closed relay action + External Warning* 3
00100110 Opened / Closed relay action + External Warning* 4
01000010 Closed / Closed relay action + Brake 4
01000100 Closed / Closed relay action + Brake 3
01000110 Opened/ Closed relay action + Brake 4
01100010 Closed / Closed relay action + Brake + External Warning* 4
01100100 Closed / Closed relay action + Brake + External Warning* 3
01100110 Opened / Closed relay action + Brake + External Warning* 4
* External warning function requires installing an external warning device such as horn and lights
to K26 Function output relay, or to K30 Function relay using the in-house designed miniature
lights and buzzer illustrated on section 4.2.6.