Installation Manual
TURNING-ON AND CONFIGURATION
36
The technical materials and information contained in this document are strictly confidential and the exclusive property of Advanced Microwave Engineering s.r.l.
These materials and information are intended solely for the purpose designated and may not be used otherwise.
It is not permitted to disclose or reproduce them in whole or in part without express written permission.
9.2.4 STEP 4 | SENSORS SEARCH
Each sensor has an unequivocal ID that must be saved to the CPU: first perform the ID SEARCH and then the SENSORS
SEARCH.
Before starting the ID SEARCH, make sure that the selectors present on the HUB and on each sensor are set to
0.
The sensors and the HUB, if they have an M12 connector, are already correctly set, and they must not be
opened.
Before starting the ID SEARCH note down the code (ID) (shown as FC: XX XX XX) indicated on each sensor in
order to be able to save it in the correct position.