Specifications
26.4V
 1
 2
 10
 9
 8
12
 3
11
 4
 7
 6
 5
56  DataMan 300 Quick Reference Guide DataMan 300 Quick Reference Guide  57
Acquisition Triggering
The acquisition trigger input on the reader is opto-isolated. To trigger 
from an NPN (pull-down) type photo-detector or PLC output, connect 
Common In to +24V and connect In to the output of the detector. 
When the output turns on, it pulls In down to 0V, turning the opto-
coupler on. 
To trigger from an PNP (pull-up) photo-detector or PLC output, connect 
In 0 to the output of the detector and connect Common In to 0V. 
When the output turns on, it pulls In 0 up to 24V, turning the opto-
coupler ON. 
In 0
Common In
I/O Cable
Pin # Signal Name Wire Color
1 Out 2 White
2 TxD Green
3 RxD Pink
4 Out 3 Yellow
5 In 1 Grey
6 Common In Black
7 Vin24 Brown
8 Vrtn Blue
9 Common Out Purple
10 In 0 Red
11 Out 0 Grey/Pink
12 Out 1 Red/Blue
The I/O cable provides access to trigger and high-
speed outputs. Unused wires can be clipped short or 
tied back using a tie made of non-conductive material. 
The above drawing shows 
the plug on the device. 